IM-TM
Description
Designed to measure gas velocity, the IM-TM turbine meter by Pietro Fiorentini incorporates an innovative method of conditioning flow in the meter body, within which a straightening section aligns the gas flow by removing undesired swirls and turbulence before they reach the turbine rotor.
Suitable for measuring non-corrosive, filtered and dry gases, including specialty gases, it is mainly used in high-pressure transmission systems and in medium and low pressure natural gas distribution networks.
IM-TM is Hydrogen Ready for NG-H2 blending.
Features
- Body: hard anodized aluminium alloy or carbon steel
- Body: Connections: ANSI 150/300/600 according to ASME B16.5, from PN16 to PN100 according to EN 1092-1
- Working temperature: from -40 °C to +55 °C for steel body
- Nominal diameters: from DN 50 to DN 200 for aluminum body, from DN 50 to DN 300 for carbon steel body
- Minimum flow rate: 8 m3/h
- Maximum flow rate: 6500 m3/h